QMZN-SCC Pro Series Wet Dust Collector | High-Power Efficient Dust Purification Solution
🔧 Core Structure & Working Principle
Working Principle & Upgrade Highlights:
-
Powerful Dust Suction: The high-power fan strongly extracts high-concentration dust-laden gas through the air inlet hose.
-
Efficient Water Curtain Purification: The air flow violently impacts the water surface of the water tank, forming a dense water curtain, and dust particles are instantly moistened and weighted.
-
Automatic Water Level Management: Integrated float ball valve automatically maintains the optimal working water level, eliminating the problem of reduced suction caused by excessive or insufficient manual water addition, ensuring more stable operation.
-
Precise Gas-Water Separation: The humid air after water washing passes through the replaceable demister (water curtain paper), which effectively separates entrained water droplets and ensures the discharged air is clean and dry.
-
Sludge Sedimentation & Collection: The purified dust settles at the bottom of the water tank and only needs to be cleaned regularly.
✨ Core Advantages Explained
|
Advantage Module
|
Technical Features & Customer Value
|
|
High-Power Customizable Solution
|
Offers flexible selection of two motor power levels: 5.5KW / 7.5KW, with a maximum processing air volume of 10562 m³/h. It can accurately match the dust output and air duct resistance of different host equipment, achieving optimal performance and energy efficiency ratio.
|
|
Efficient & Stable Water Filtration System
|
Adopts high-efficiency water curtain filtration as the core, with a purification efficiency of ≥97%. The float ball valve automatic water level control eliminates the tediousness and errors of manual water level monitoring, ensuring the equipment continuously operates at the best working condition.
|
|
Modular Design for Easy Maintenance
|
The demister (water curtain paper) adopts a standardized modular design, featuring easy replacement and a clear cycle (approximately 6 months to 1 year). It effectively maintains gas-water separation efficiency and guarantees long-term stable operation.
|
|
Strong Suction & Large Air Volume
|
With an air pressure of up to 2554-1673 Pa and a wide air volume range, it maintains strong dust collection capacity even with longer pipelines (3-3.5 meters recommended), enabling more flexible layout.
|
|
Robust Industrial-Grade Structure
|
The main body is made of a reinforced carbon steel structure (2.0mm lower body), with an overall weight of 560KG. It has a stable structure, is designed for continuous operation in industrial environments, and has a long service life.
|
|
Intelligent Operation Experience
|
From automatic water supply to modular maintenance, the design embodies user-friendliness everywhere, reducing requirements for operators' skills and daily maintenance workload.
|
📋 Principal Technical Parameters
|
Item
|
Specification Details
|
|
Product Series
|
QMZN-SCC Pro (Wet Type)
|
|
Rated Power
|
Customizable: 5.5 kW or 7.5 kW
|
|
Power Supply Voltage
|
380V / 50Hz
|
|
Processing Air Volume
|
5712 – 10562 m³/h
|
|
Air Pressure Range
|
2554 – 1673 Pa
|
|
Filtration Method
|
Water Filtration
|
|
Filtration Efficiency
|
≥ 97%
|
|
Equipment Material
|
Carbon Steel (Lower Body Plate Thickness: 2.0mm, Upper Body Plate Thickness: 1.5mm)
|
|
Equipment Dimensions (L×W×H)
|
1700 × 1325 × 2305 mm
|
|
Equipment Weight
|
Approx. 560 kg
|
|
Noise Level
|
≤ 78 dB(A)
|
|
Water Level Control
|
Float Ball Valve Automatic Control
|
|
Core Consumables
|
Demister (Water Curtain Paper)
|
|
Starting Method
|
Direct Start
|
⚙️ Operation, Maintenance & Safety Guidelines
Four-Step Startup Process:
-
Electrical Connection: Confirm the motor power model, and correctly connect the equipment power cord (three-phase) to the 380V power supply according to the phase sequence (blue, red, yellow for forward rotation).
-
Pipeline Connection: Use a hose of appropriate diameter to connect the host dust source and the dust collector air inlet. To achieve optimal performance, it is recommended to control the hose length within 3-3.5 meters.
-
Water Injection Initialization: Connect the water pipe to the water inlet (1/2 inch interface) and turn on the water source. The equipment will automatically inject water to the preset optimal level through the float ball valve and then stop, requiring no manual intervention.
-
Startup Operation: After completing the above steps, power on and start the equipment.
Key Maintenance & Precautions:
-
Regular Water Tank Cleaning: A thorough cleaning must be performed at least once a month. After turning off the power, open the equipment maintenance port to remove sludge and impurities deposited in the water tank to ensure filtration efficiency and prevent clogging.
-
Core Consumable Replacement: The demister (water curtain paper) is a key maintenance component. Please inspect and replace it every 6 months to 1 year according to the actual usage frequency to ensure gas-water separation effect and smooth exhaust.
-
Operation Monitoring: Daily observe whether the equipment operates with stable noise and check if the automatic water level is normal. When not in use for a long time, drain the water tank.
📦 Service Support
-
Selection Consultation: Provide professional power selection and configuration suggestions based on your host model and workshop layout.
-
Installation Guidance: Provide detailed electrical and pipeline installation guidelines.
-
Consumable Supply: Supply original maintenance consumables such as demisters (water curtain paper).